Nhà Sản phẩmMini Circuit Breaker

Electronic Residual Circuit Breaker with Over Current Protection RCBO

Chứng nhận
Trung Quốc Shenzhen City Breaker Co., Ltd. Chứng chỉ
Trung Quốc Shenzhen City Breaker Co., Ltd. Chứng chỉ
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

Tôi trò chuyện trực tuyến bây giờ

Electronic Residual Circuit Breaker with Over Current Protection RCBO

Electronic Residual Circuit Breaker with Over Current Protection RCBO
Electronic Residual Circuit Breaker with Over Current Protection RCBO

Hình ảnh lớn :  Electronic Residual Circuit Breaker with Over Current Protection RCBO

Thông tin chi tiết sản phẩm:
Place of Origin: China
Hàng hiệu: KRIPAL
Chứng nhận: CE
Model Number: UKB7LE
Thanh toán:
Minimum Order Quantity: 1000 pcs
Giá bán: negotiable
Packaging Details: 12 poles packed in one small box and then in carton
Delivery Time: 20 days and depends on ordering quantity
Payment Terms: T/T, L/C
Supply Ability: 200000 pcs per month
Chi tiết sản phẩm
Breaking capacity: 10 kA Poles available: 1P, 2P, 3P, 3P+N, 4P
Ampere: 6A,10A,16A,20A,25A,32A,40A,50A,63A Residual protection: Yes
Overload protection: Yes Type: mini circuit breaker
Điểm nổi bật:

Micro Circuit Breaker

,

Compact Circuit Breaker

 
Electronic Residual Circuit Breaker with Over Current Protection RCBO
 
RCBOs are commonly used in applications where there is the need to combine protection against overcurrents (overload and short-circuit) and protection against earth leakage currents.
RCBOs help in sensing this kind of faults and trip the circuit ensuring complete protection of the people and connected equipments. 
 
 
Desctription:
 
Electronic type residual current circuit breaker from the tripper RCD and UKB7-63-tye mini circuit breaker MCB made assembling stable performance beautiful appearance. For the circuit the human body to electric shock, isolation and destruction earth leakage fault and short circuit, overload protection, full-featured. Efficient appliances and equipment to protect the safe use of electricity, UKB7LE-63 series leakage circuit breakers in the short-circuit, overload protection and electrical properties of the principle of respect with the corresponding rated the same as a small circuit breaker
 
 
Specifications:

 
Technology Specification & Electrical Specification
Electric standardIEC61009; GB 16917.0
Trip timeNon-time delay; Minimal 10ms time delay
Rated voltage230V; 50HZ          230V/400V
Rated surplus operating current10; 30; 100; 300mA
Selection grade3
Rated braking capacity10kA
Rated current6-63A
Tripping characterB, C, D characteristic curve
Maximum connected fuse100A gL(> 10kA)
Environment  capabilityAccording to the IEC 1008 standard
Case protection gradeIP40 after installation
Electric lifeNot less than 4000 times of breaking and closing
Mechanical lifeNot less than 2000 times of breaking and closing
Mechanical Parameter
Installation modeInstallation at the DIN guide rail of 35mm
Terminal block capacityGeneratrix thickness 0.8-2mm

 
 
 
Main benefits:
  
High quality
Complete range
 
Main Features:  
 
AC, A, type available
Wide range of breaking capacities for application from residential to industrial field
Rated Currents up to 63 A and poles configuration for applications in Single Phase as well as Three Phases networks
Current:6A,10A,16A,20A,25A,32A,40A,50A,63A
 
Breaking capactity: 10KA
 
Rated leakage current: 10mA, 30mA, 100mA, 300mA
 
Curve: B, C, D
 
 
Instantaneous tripping current:
 
International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:
 

    Type

Instantaneous tripping current

       B

above 3 In up to and including 5 In

       C

above 5 In up to and including 10 In

       D

above 10 In up to and including 20 In

 